Evaluation of the Teledyne ADQ32 Card for Thomson Scattering Diagnostics

AUG Seminar

  • Datum: 02.07.2025
  • Uhrzeit: 12:55 - 13:25
  • Vortragender: César Gonzalez
  • Universidad Politécnica de Madrid
  • Ort: L6 II
  • Raum: Seminarraum L6, 2.Stock Süd
Teledyne SP Devices has developed high-performance data acquisition systems that integrate an open FPGA to enable real-time signal processing. This work explores the feasibility of implementing the Thomson scattering dispersion algorithm directly on the FPGA of theADQ32 digitizer. The algorithm was developed using high-level synthesis (HLS), while a hardware description language (HDL) was used to interface with the ADQ signal architecture. A dedicated control program was built within the Discharge Control System (DCS), leveraging the API provided by Teledyne to configure and operate the card. The FPGA-based implementation produced results identical to the C++ version of the algorithm, with an execution time of 170μs, demonstrating its potential for real-time plasma diagnostics.